Search results for " three-dimensional"

showing 10 items of 323 documents

Retroaortic left renal vein joining the left common iliac vein

2000

Retroaortic left renal vein joining the left common iliac vein is a rare congenital anomaly in the development of the inferior vena cava. To our knowledge, only one case has been reported in the literature; however, its imaging features have never been described. A 27-year-old male presented with a 1-year history of recurrent right flank pain, dysuria, hematuria, and fever (39 degrees C). Computed tomography and MR venography showed a retroaortic left renal vein joining the left common iliac vein. We present the CT and MR venography findings and discuss their feasibility in showing this congenital anomaly.

AdultMalemedicine.medical_specialtyVena Cava InferiorIliac Veinurologic and male genital diseasesInferior vena cavaRenal VeinsMagnetic resonance angiographyImaging Three-DimensionalmedicineLeft common iliac veinHumansDysuriaRadiology Nuclear Medicine and imagingNeuroradiologyKidneymedicine.diagnostic_testbusiness.industryLeft renal veinInterventional radiologyGeneral MedicineAnatomymedicine.anatomical_structuremedicine.veincardiovascular systemRadiologymedicine.symptomTomography X-Ray ComputedbusinessMagnetic Resonance AngiographyEuropean Radiology
researchProduct

Post-extraction mesio-distal gap reduction assessment by confocal laser scanning microscopy - a clinical 3-month follow-up study

2017

[EN] AimThe aim of this 3-month follow-up study is to quantify the reduction in the mesio-distal gap dimension (MDGD) that occurs after tooth extraction through image analysis of three-dimensional images obtained with the confocal laser scanning microscopy (CLSM) technique. Materials and MethodsFollowing tooth extraction, impressions of 79 patients 1month and 72 patients 3months after tooth extraction were obtained. Cast models were processed by CLSM, and MDGD changes between time points were measured. ResultsThe mean mesio-distal gap reduction 1month after tooth extraction was 343.4m and 3months after tooth extraction was 672.3m. The daily mean gap reduction rate during the first term (bet…

AdultMaleAdolescentPost-extraction changesESTADISTICA E INVESTIGACION OPERATIVAINGENIERIA QUIMICAYoung Adult03 medical and health sciencesImaging Three-Dimensional0302 clinical medicinestomatognathic systemImage Interpretation Computer-AssistedSocket healingConfocal laser scanning microscopyHumansMedicineMesio-distal distanceConfocal laser scanning microscopyProspective Studies030212 general & internal medicineTooth SocketAgedMicroscopy Confocalbusiness.industry030206 dentistryMiddle AgedTooth ExtractionPeriodonticsFemaleNuclear medicinebusinessGap reductionFollow-Up StudiesMonth follow up
researchProduct

Advanced microscopy analysis of the micro-nanoscale architecture of human menisci

2019

AbstractThe complex inhomogeneous architecture of the human meniscal tissue at the micro and nano scale in the absence of artefacts introduced by sample treatments has not yet been fully revealed. The knowledge of the internal structure organization is essential to understand the mechanical functionality of the meniscus and its relationship with the tissue’s complex structure. In this work, we investigated human meniscal tissue structure using up-to-date non-invasive imaging techniques, based on multiphoton fluorescence and quantitative second harmonic generation microscopy complemented with Environmental Scanning Electron Microscopy measurements. Observations on 50 meniscal samples extract…

Materials sciencemultiphoton imaging SHG meniscus collagen elastin enviromental semScience0206 medical engineeringBiophysicslcsh:MedicineRegular wave02 engineering and technologyMenisci TibialArticleBiophysical Phenomena03 medical and health sciences0302 clinical medicineImaging Three-DimensionalCollagen fibresMicroscopyHumansMeniscuslcsh:ScienceEnvironmental scanning electron microscopeNanoscopic scaleMicroscopyMultidisciplinaryMeniscal tissuebiologylcsh:RQR030229 sport sciencesSecond Harmonic Generation Microscopy020601 biomedical engineeringSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Elastinbiology.proteinMicroscopy Electron ScanningMedicinelcsh:QCollagenAnatomySettore ICAR/08 - Scienza Delle CostruzioniElastinBiomedical engineeringScientific Reports
researchProduct

Valutazione quantitativa tridimensionale del parenchima polmonare affetto da fibrosi cistica : risultati preliminari

2007

Purpose. The aim of this study was to assess the feasibility of three-dimensional (3D) reconstructions and quantitative analysis of the volume of each component of the lung with cystic fibrosis (CF). Materials and methods. Twenty-two patients with CF (mean age 17±8 yeas) were included in the study. The patients underwent an unenhanced single-slice spiral computed tomography (CT) chest scan with the following parameters: collimation 3 mm, table feed 6 mm×rot-1, reconstruction interval 1 mm, soft tissue reconstruction kernel. Four image data sets were obtained: native axial slices, cine-mode display, virtual bronchographic volumerendered images with algorithm for tissue transition display and…

Cystic fibrosis CT densitometry Volume rendering three-dimensional Segmentation
researchProduct

Harmonized benchmark labels of the hippocampus on magnetic resonance: The EADC-ADNI project

2015

Abstract Background A globally harmonized protocol (HarP) for manual hippocampal segmentation based on magnetic resonance has been recently developed by a task force from European Alzheimer's Disease Consortium (EADC) and Alzheimer's Disease Neuroimaging Initiative (ADNI). Our aim was to produce benchmark labels based on the HarP for manual segmentation. Methods Five experts of manual hippocampal segmentation underwent specific training on the HarP and segmented 40 right and left hippocampi from 10 ADNI subjects on both 1.5 T and 3 T scans. An independent expert visually checked segmentations for compliance with the HarP. Descriptive measures of agreement between tracers were intraclass cor…

MaleInservice TrainingEpidemiologyIntraclass correlationNeuroimagingHippocampusCellular and Molecular Neuroscienceddc:616.89Imaging Three-DimensionalDevelopmental NeuroscienceNeuroimagingSimilarity (network science)Alzheimer DiseasemedicineImage Processing Computer-AssistedHumansSegmentationCognitive DysfunctionHARPAgedAged 80 and overmedicine.diagnostic_testbusiness.industryHealth PolicyReproducibility of ResultsMagnetic resonance imagingPattern recognitionOrgan SizeMagnetic Resonance ImagingConfidence intervalPsychiatry and Mental healthBenchmark (computing)FemaleNeurology (clinical)Artificial intelligenceGeriatrics and GerontologyAtrophybusinessPsychologyNeuroscience
researchProduct

A new system for the representation of places hit by disasters

2010

This paper analyses a new system for data collection and management after a disaster. In particular, the system enables to represent what exists in a place, and to visualize the preceding state, in a synoptic vision before and after the event; and also enables the consultation of synthetic information, the possibility of connections to internet sites for further in depth analysis and then the possibility of archiving and retrieving data through researching specific items. This is carried out in a simple and quick way, utilizing a portable device. The obtained product is consultable on site, or otherwise memorized and archived. Because of all these functions, it could be a useful instrument …

GNSS digital compass three-dimensional model disaster management data collection.
researchProduct

Cephalometric measurements from 3D reconstructed images compared with conventional 2D images

2011

Abstract Objective: To assess whether the values of different measurements taken on three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) are comparable with those taken on two-dimensional (2D) images from conventional lateral cephalometric radiographs (LCRs) and to examine if there are differences between the different types of CBCT software when taking those measurements. Material and Methods: Eight patients were selected who had both an LRC and a CBCT. The 3D reconstructions of each patient in the CBCT were evaluated using two different software packages, NemoCeph 3D and InVivo5. An observer took 10 angular and 3 linear measurements on each of the three types o…

AdultMale2d imagesAdolescentCephalometryRadiographyDentistryOrthodonticsComputed tomographyImage processingMandibleYoung AdultImaging Three-DimensionalImage Processing Computer-AssistedMaxillamedicineHumansNasal BoneSella TurcicaChildMathematicsObserver VariationOrthodonticsmedicine.diagnostic_testPalatebusiness.industryIntraobserver reliabilityReproducibility of ResultsOriginal ArticlesCone-Beam Computed TomographyIncisorFaceMandibular planeFemalebusinessObserver variationSoftwareThe Angle Orthodontist
researchProduct

Navigated percutaneous screw fixation of the pelvis with O-arm 2: two years' experience.

2020

Aim To evaluate the case series of the patients operated with percutaneous fixation by the navigation system based on 3D fluo-roscopic images, to assess the precision of a surgical implant and functional outcome of patients. Methods A retrospective study of pelvic ring fractures in a 2-year period included those treated with the use of the O-Arm 2 in com-bination with the Stealth Station 8. Pelvic fractures were classifi-ed according to the Tile and the Young-Burgess classification. All patients were examined before surgery, with X-rays and CT scans, and three days after surgery with additional CT scan. The positioning of the screws was evaluated according to the Smith score, the outcome wi…

Sacrum3D-fluoroscopic navigationBone ScrewsPelvisIliosacral fixationFracture Fixation InternalImaging Three-DimensionalSurgery Computer-AssistedO-arm Stealth Station S8Fragility fracture of pelvisHumansPelvic ring fracturesTomography X-Ray ComputedRetrospective StudiesMedicinski glasnik : official publication of the Medical Association of Zenica-Doboj Canton, Bosnia and Herzegovina
researchProduct

Forefoot strikers exhibit lower running-induced knee loading than rearfoot strikers.

2013

AB Purpose: Knee pain and Achilles tendinopathies are the most common complaints among runners. The differences in the running mechanics may play an important role in the pathogenesis of lower limb overuse injuries. However, the effect of a runner's foot strike pattern on the ankle and especially on the knee loading is poorly understood. The purpose of this study was to examine whether runners using a forefoot strike pattern exhibit a different lower limb loading profile than runners who use rearfoot strike pattern. Methods: Nineteen female athletes with a natural forefoot strike (FFS) pattern and pair-matched women with rearfoot strike (RFS) pattern (n = 19) underwent 3-D running analysis …

medicine.medical_specialtyHeelAdolescentPhysical Therapy Sports Therapy and RehabilitationAchilles TendonRunningWeight-BearingPatellofemoral JointYoung AdultImaging Three-DimensionalKnee loadingMedicineHumansOrthopedics and Sports MedicineAnkle Injuriesta315OrthodonticsAchilles tendonbusiness.industryFootForefootmedicine.anatomical_structureKnee painCoronal planePhysical therapyFemaleStress MechanicalFoot Injurymedicine.symptomAnklebusinesshuman activitiesAnkle JointMedicine and science in sports and exercise
researchProduct

Three-dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions

2016

Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely “bicuspid aortopathy”) is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting fr…

MalePatient-Specific ModelingBicuspid aortic valveComputed Tomography AngiographyHeart Valve DiseasesBiomedical EngineeringMedicine (miscellaneous)Bioengineering—Three-dimensional anatomic reconstructionElectrocardiographyImaging Three-DimensionalBicuspid Aortic Valve DiseaseSettore ING-IND/12 - Misure Meccaniche E TermicheHumans—Finite-element analysiProspective StudiesAortaAgedRetrospective Studies—Aortic failureHemodynamicsModels CardiovascularComputational BiologySettore ING-IND/34 - Bioingegneria IndustrialeMiddle AgedBiomaterialAortic Aneurysm—Ascending thoracic aortic aneurysmAortic ValveFemaleStress MechanicalSoftware
researchProduct